The Effect of Variations of Serum Examination Time Lapse on Electrolyte Levels of Potassium and Chloride Pengaruh Variasi Selang Waktu Pemeriksaan Serum Terhadap Kadar Elektrolit Kalium dan Klorida

Main Article Content

Nur Indah Nila Asri
Andika Aliviameita

Abstract

Electrolyte is a chemical substance that dissociates in the liquid into charged particles of positive and negative ions. In the laboratory, conditions are often found that make an examination not immediately carried out after sampling. The purpose of this study was to determine the effect of variations in serum examination time intervals on Potassium and Chloride electrolyte levels for 0, 4, 8 and 24 hours at room temperature (20-25℃). This study used a laboratory experimental method with a sample of 32 samples. This research was conducted at the Bhayangkara Hospital Pusdik Brimob Watukosek Laboratory. Examination of Potassium and Chloride electrolyte levels using the OPTI CCA-TS Analyzer. The results of the One Way Anova test for Potassium electrolyte levels obtained a significance p value of = 0,199 meaning that there was no effect of variations in serum examination time intervals on Potassium electrolyte levels, while Chloride electrolyte levels obtained a significance value of p = 0,002 meaning that there is an effect of variations in serum examination time intervals on Chloride electrolyte levels.

Article Details

How to Cite
Asri, N. I. N., & Aliviameita, A. (2022). The Effect of Variations of Serum Examination Time Lapse on Electrolyte Levels of Potassium and Chloride. Medicra (Journal of Medical Laboratory Science/Technology), 5(2), 119-123. https://doi.org/10.21070/medicra.v5i2.1639
Section
Articles

References

Apriliani, I. (2018). Perbedaan Kadar Elektrolit (Na, K, Cl) Pada Sampel Segera dan Ditunda 150 Menit. Skripsi. Universitas Muhammadiyah Semarang. Semarang. Retrieved from http://repository.unimus.ac.id/2917
Asirvatham, J. R., Moses, V., & Bjornson, L. (2013). Errors in Potassium Measurement: A Laboratory Perspective for the Clinician. North American Journal of Medical Sciences, 5(4), 255-259. Retrieved from https://pubmed.ncbi.nlm.nih.gov/23724399/
Azizah, N., & Aliviameita, A. (2019). Pengaruh Lama Penundaan pemeriksaan Serum Terhadap kadar Elektrolit Natrium dan Klorida. Journal of Medical Laboratory Science Technology, 2(1), 28-30. Retrieved from http://ojs.umsida.ac.id/index.php/medicra/article/view/2589/1741
Baruah, A., Goyal, P., Sinha, S., Ramesh, K. L., & Datta, R. (2014). Delay in Specimen Processing-Major Source of Preanalytical Variation in Serum Electrolytes. Journal of Clinical and Diagnostic Research, 8(12), 1-3. doi: 10.7860/JCDR/2014/10150.5285
Bobby, L., Boyanton, Jr., & Blick, K. E. (2002). Stability Studies of Twenty-Four Analytes in Human Plasma and Serum. Clinical Chemistry, 48(12), 2242-2247. Retrieved from https://pubmed.ncbi.nlm.nih.gov/12446483/
Burtis, A. C., Edward, R. & Bruns, E. D. (2008). Tietz Fundamental of Clinical Chemistry. (6 Edn). Philadelphia: Elsevier.
Departemen Kesehatan RI. (2008). Pedoman Praktek Laboratorium yang Benar (Good Laboratory Practice). Jakarta: Departemen Kesehatan RI
Hartini, S., & Suryani, M. E. (2016). Uji Kualitas Simpanan terhadap Kadar Kolesterol Dalam Darah Di Poltekkes Kemenkes Kaltim. Jurnal Ilmiah Manuntung, 2(1), 65-69. Retrieved from: https://jurnal.akfarsam.ac.id/index.php/jim_akfarsam/article/view/49
Kee, J. L. (2007). Pedoman Pemeriksaan Laboratorium dan Diagnostik. Edisi 6. Jakarta: EGC.
Sari, R. E. N. I. (2018). Perbedaan Lama Penundaan Serum Terhadap Kadar Kalium. Karya Tulis Ilmiah. Universitas Muhammadiyah Surabaya. Surabaya. Retrieved from http://repository.um-surabaya.ac.id/2735/
Vijayasamundeeswari, C. K., Ananthi, N., & Sudha, R. (2017). Comparison of electrolyte levels in serum and plasma. International Journal of Clinical Biochemistry and Research, 4(2), 115-118. doi: https://doi.org/10.18231/2394-6377.2017.0027
Yaswir, R., & Ferawati, I. (2012). Fisiologi dan Gangguan Keseimbangan Natrium, Kalium dan Klorida serta Pemeriksaan Laboratorium. Jurnal Kesehatan Andalas, 1(2), 80-85. Retrieved from http://jurnal.fk.unand.ac.id/index.php/jka/article/view/48
Yustiani, N. T., Mutmainnah, Pakasi, R. DN., & Hardjoeno. (2009). Kadar Na, k, Cl Pada Ragam (Variasi) Selang Waktu Pemeriksaan Serum. Indonesian Journal of Clinical Pathology and Medical Laboratory, 15(2), 49-51. Retrieved from https://indonesianjournalofclinicalpathology.org/index.php/patologi/article/view/945